Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 16(9): e0253090, 2021.
Article in English | MEDLINE | ID: mdl-34543278

ABSTRACT

BACKGROUND: Background Population-based data on SARS-CoV-2 infection in pregnancy and assessment of passive immunity to the neonate, is lacking. We profiled the maternal and fetal response using a combination of viral RNA from naso-pharyngeal swabs and serological assessment of antibodies against SARS-CoV-2. METHODS: This multicentre prospective observational study was conducted between March 24th and August 31st 2020. Two independent cohorts were established, a symptomatic SARS-CoV-2 cohort and a cohort of asymptomatic pregnant women attending two of the largest maternity hospitals in Europe. Symptomatic women were invited to provide a serum sample to assess antibody responses. Asymptomatic pregnant women provided a nasopharyngeal swab and serum sample. RT-PCR for viral RNA was performed using the Cobas SARS-CoV-2 6800 platform (Roche). Umbilical cord bloods were obtained at delivery. Maternal and fetal serological response was measured using both the Elecsys® Anti-SARS-CoV-2 immunoassay (Roche), Abbott SARS-CoV-2 IgG Assay and the IgM Architect assay. Informed written consent was obtained from all participants. RESULTS: Ten of twenty three symptomatic women had SARS-CoV-2 RNA detected on nasopharyngeal swabs. Five (5/23, 21.7%) demonstrated serological evidence of anti-SARS-CoV-2 IgG antibodies and seven (30.4%, 7/23) were positive for IgM antibodies. In the asymptomatic cohort, the prevalence of SARS-CoV-2 infection in RNA was 0.16% (1/608). IgG SARS-CoV-2 antibodies were detected in 1·67% (10/598, 95% CI 0·8%-3·1%) and IgM in 3·51% (21/598, 95% CI 2·3-5·5%). Nine women had repeat testing post the baseline test. Four (4/9, 44%) remained IgM positive and one remained IgG positive. 3 IgG anti-SARS-CoV-2 antibodies were detectable in cord bloods from babies born to five seropositive women who delivered during the study. The mean gestation at serological test was 34 weeks. The mean time between maternal serologic positivity and detection in umbilical cord samples was 28 days. CONCLUSION: Using two independent serological assays, we present a comprehensive illustration of the antibody response to SARS-CoV-2 in pregnancy, and show a low prevalence of asymptomatic SARS-CoV2. Transplacental migration of anti-SARS-CoV-2 antibodies was identified in cord blood of women who demonstrated antenatal anti-SARS-CoV-2 antibodies, raising the possibility of passive immunity.


Subject(s)
COVID-19/diagnosis , COVID-19/immunology , Delivery, Obstetric , SARS-CoV-2/immunology , Antibody Formation/immunology , COVID-19/genetics , COVID-19/virology , Female , Fetal Blood/metabolism , Follow-Up Studies , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Longitudinal Studies , Pregnancy , Prospective Studies
2.
Pract Lab Med ; 25: e00217, 2021 May.
Article in English | MEDLINE | ID: mdl-33898687

ABSTRACT

BACKGROUND: Troponin is a widely used cardiac protein biomarker for acute coronary syndrome. Its increasing importance drives an increasing need to assess, in real-world conditions, the performance of the tests to measure it. We evaluated the performance characteristics of high-sensitivity troponin I assay reagents and ancillary agents on the Abbott ARCHITECT ci4100, ARCHITECT i2000SR and Alinity ci using historical quality control data spanning 5 years. DESIGN AND METHOD: Retrospective diagnostic hs-TnI quality control data were collected between 2015 and 2019 from the Abbott ARCHITECT ci4100, ARCHITECT i2000SR and Alinity ci located in the University College Dublin Clinical Research Centre Core Lab facility. Descriptive statistics for bias and variability were generated. Linear regression models were used to calculate the mean hs-TnI concentrations over Abbott quality control or reagent lot age and over time from the last calibration of the analysers. RESULTS: Measurement bias on all three systems ranged between -2.49% and 3.98%. The total CV was ≤8.80%, with a within-lot variability for the reagents and controls of ≤5.45% and ≤7.13%, respectively. The between-lot CVs for reagents and controls were ≤7.16% and 6.19%, respectively. The effect of control or reagent age did not greatly affect stability over time. Results were also stable over different times from the last calibration of the analysers. CONCLUSION: The results of this study show that the Abbott hs-TnI assay on the ARCHITECT i2000sr and ARCHITECT ci4000 systems is quite stable in a core laboratory environment. The Alinity ci system exhibits similar performance characteristics.

SELECTION OF CITATIONS
SEARCH DETAIL
...